Ambient conditions
The temperature and humidity of the surrounding air in the space being monitored, as opposed to the air going into or coming out of a machine.
Why it matters: Ambient readings are the baseline. Comparing them with a dehumidifier's outlet air shows whether the equipment is doing its job.
#
Dry bulb temperature
The air temperature as read by an ordinary thermometer. When people say "temperature" without qualification, this is what they mean.
#
Relative humidity (RH)
How much water vapour the air holds compared with the most it could hold at that temperature, shown as a percentage. Warm air can hold more water than cold air, so RH changes when temperature changes even if the amount of moisture stays the same.
Why it matters: Because RH moves with temperature, it can mislead on its own. Restorers pair it with GPP to see whether moisture is actually being removed.
#
Dew point
The temperature at which air becomes saturated and water starts to condense. If a surface is colder than the dew point of the air around it, moisture will form on it.
Why it matters: A falling dew point means the air is getting drier. Surfaces below the dew point risk condensation, which can lead to secondary damage.
#
Wet bulb temperature
The temperature read by a thermometer wrapped in a water-soaked wick with air moving over it. Evaporation cools the wick, so the drier the air, the lower the wet bulb reads compared with the dry bulb. At 100% RH the two readings are the same.
#
Grains per pound (GPP)
The actual weight of water vapour in the air, measured in grains of water per pound of dry air. There are 7,000 grains in a pound. Unlike RH, GPP does not change when the air heats up or cools down; it only changes when moisture is added or removed.
Why it matters: GPP is the clearest single number for tracking drying progress over the life of a job.
#
Grain depression
The difference in GPP between the air entering a dehumidifier and the air leaving it. For example, air entering at 80 GPP and leaving at 45 GPP is a grain depression of 35.
Why it matters: It is a direct measure of how hard a dehumidifier is working. A drop in grain depression with no change in conditions can point to a problem with the unit.
#
Psychrometrics
The study of air and the water vapour in it. Temperature, RH, dew point, wet bulb and GPP are all linked: if you know two of them, the rest can be calculated. A psychrometric chart plots these relationships on one graph.
#
Moisture content (MC)
The amount of water held in a material such as wood, drywall or concrete, measured with a moisture meter. For wood it is usually shown as a percentage of the wood's dry weight.
#
Drying goal
The moisture reading a material needs to reach before drying is considered complete, usually set by measuring the same material in an unaffected area of the building (sometimes called the dry standard).
#
IICRC S500
The industry standard for professional water damage restoration, published by the Institute of Inspection, Cleaning and Restoration Certification. It defines categories of water (by contamination level) and classes of water damage (by how much water and evaporation load is involved), and sets out drying and documentation practices.
#